Check 3 phase (big) power cords, are they securely plugged in?
The plugs can be on the floor or back wall behind grill
Ensure the plugs are completely engaged in outlet - picture of plugs on this page
2. Check 50amp Breakers and reset if needed - instructions here
3. If above steps did not resolve issue and:
Is it between 7am and 5pm
Final Step
Outside those hours
Only 1 platen down
Final Step
Two or more platens are down
Final Step
3 Phase Plugs
3 Phase Plug Properly Secured
Check interlock ( twist lock ) power cord. Ensure it is fully engaged in outlet - picture of plug on this page
Is hood running? To confirm if hood is running:
Take a paper towel and place on hood.
If paper towel holds in place, hood is on. - picture on this page
If paper towel falls, hood is off
If hood is not on check breakers - instructions here
If above steps did not resolve issue - Final Step
Hood Check - hood is on
Interlock Plug
Interlock Plug Properly Secured
Do not use platen for affected display
Turn off main power switch
Wait for 30 seconds
Turn main power switch back on
Try to raise and lower platen
If issue persists and:
Only 1 platen down
Final Step
Two or more platens are down
Final Step
Turn main power switch off
Wait 1 minute
Turn main power switch back on
3. If above steps did not resolve issue and:
Is it between 7am and 5pm
Final Step
Outside those hours and:
Only 1 platen down
Final Step
Two or more platens are down
Final Step
If it is between 7am and 5pm:
Final Step
Outside those hours:
Final Step