Ensure register 14 is turned on and shows ' Waystation Online' across the very top of the register (gray bar)
If register 14 shows 'Waystation Offline' follow the Single register shows "waystation: offline" steps here
Check network cable on register 14 has orange and green light
If no light, reseat the cable by unplugging and plugging it back in
If still no light, reboot register 14
Click on Manager - scan finger
Click on Manager Options
Click on Reboot POS
Power Cycle ABS
Locate the power switch on the ABS unit (picture on this page)
Power off the ABS unit
Wait for 30 seconds
Power on the ABS unit
Check other ABS (if you have one) and lobby drinks to ensure they are dispensing properly. If none of them are dispensing correctly - Final Step
If none of the above steps resolve issue, put machine in manual mode and dispense drinks manually and follow this Final Step
Locate power button on front bottom left of ABS (Drain pan might be blocking and may need to be moved to access - picture on this page)
Toggle the switch off
Wait 30 seconds
Toggle the switch on
Wait for ABS to boot up
If it is still not dropping cups and:
Is it between 7am and 5pm:
Final Step
Outside those hours
Final Step
7. Use other drink filling options within store (lobby self serve or other ABS) for intern time
Follow these steps to check CO2
If after following the CO2 steps there is still no carbonation
Is ice maker full?
Is ice chute cover on? - picture on this page
If ice is full and chute cover is on but still not dispensing
remove ice chute cover
push the silver ice gate in and out a few times - picture on this page
put ice chute cover back on
4. If ice still not dispensing - Final step
Use other ABS or manually fill cups with ice for intern time
Ice Chute
Silver Ice Gate
Is it between 7am and 5pm
Final Step
Outside those hours
Final Step
Use other drink filling options within store (lobby self serve or other ABS) for intern time
If other drink filling options also taste wrong
Final Step
Remove top cover of conveyor by unscrewing three screws in middle of conveyor (picture on this page)
Remove conveyor from abs (picture on this page)
Ensure end of conveyor that has metal tab at bottom is at the same side on the same side as the cutout in abs (picture on this page)
Adjust conveyor belt so metal tab aligns with cutout (picture on this page)
Ensure conveyor is fully seated
Reattach cover of the conveyor
If conveyor still isn't moving
Locate the sensor at front left of ABS
Take napkin and wipe any residue
Take second napkin and apply hand sanitizer to it
Use second napkin to wipe off front of sensor
If conveyor still isn't moving
Is it between 7am and 5pm:
Final Step
Outside those hours
Final Step
Use other drink filling options within store (lobby self serve or other ABS) for intern time
Remove Top Cover of Conveyor
Conveyor Removed
Metal Tab at Bottom of Conveyor - Line Up with White Cutout on Left Side of ABS
White Cutout on Left Side of ABS
ABS Sensor
If it is between 7am and 5pm:
Final Step
Outside those hours:
Final Step